Home Categories Send inquiry

Special Price for Air Pressure Transmitter - WP401BS Micro Cylindrical Customized Output Pressure Transmitter – Wangyuan

WP401BS Tiny Size Pressure Transmitter can be used to measure & control gauge, absolute, negative or sealed pressure on process systems in the fields such as
  • ✦ Automotive Industry
  • ✦ Environmental Science
  • ✦ Mechanical Engineering
  • ✦ HVAC and Duct System
  • ✦ Booster Pump Station
  • ✦ Oleochemical Industry
  • ✦ Gas Gathering Station
  • ✦ Industrial Gases Storage
WP401BS Pressure Transmitter is small and flexible, compatible with a variety of complex mounting sites. M12 aviation plug, Hirshcmman DIN or other adapted connector provides convenient wiring and handy installation. Its output signal can be set to mV voltage output instead of standard 4~20mA signal. Cylindrical robust housing made of stainless steel achieves IP65 protection grade and can be improved to IP68 with submersible cable lead. Customization demands on structure, material, power supply and other aspects of the instrument are also very welcome. Miniature size and lightweight Low power consumption Excellent accuracy class Customized mV voltage output Compact dimension design Comprehensive factory calibration  
Item name WP401BS Micro Cylindrical Customized Output Pressure Transmitter
Model WP401BS
Measuring range 0—(± 0.1~±100)kPa, 0 — 50Pa~400MPa
Accuracy 0.1%FS; 0.2%FS; 0.5 %FS
Pressure type Gauge; Absolute; Sealed; Negative
Process connection 1/4BSPP, G1/2”, 1/4"NPT, M20*1.5, G1/4”, Customized
Electrical connection Aviation plug; Waterproof cable lead; Cable gland; Hirschmann(DIN),  Customized
Output signal mV; 4-20mA(1-5V); Modbus RS-485; HART; 0-10mA(0-5V); 0-20mA(0-10V), Customized
Power supply 24(12-30)VDC; 220VAC, 50Hz
Compensation temperature -10~70℃
Operating temperature -40~85℃
Explosion-proof Intrinsically safe Ex iaIICT4 Ga;  Flameproof safe Ex dbIICT6 Gb
Material Electronic case: SS304, Customized
Wetted part: SS304/316L; PTFE; Hastelloy, Customized
Diaphragm: SS304/316L; Ceramic; Tantalum, Customized
Medium Liquid, Gas, Fluid
Overload capacity Measurement upper limit Overload Long term stability
<50kPa 2~5 times <0.5%FS/year
≥50kPa 1.5~3 times <0.2%FS/year
Note: When range <1kPa, only no corrosion or weak corrosive gas can be measured.
For more information about WP401BS Small Size Pressure Transmitter please feel free to contact us.